{"id":45,"date":"2015-06-08T20:27:05","date_gmt":"2015-06-08T20:27:05","guid":{"rendered":"http:\/\/www.gratingworks.com\/?page_id=45"},"modified":"2020-07-14T20:00:42","modified_gmt":"2020-07-14T20:00:42","slug":"concavus-spectrometers","status":"publish","type":"page","link":"https:\/\/www.gratingworks.com\/zh\/products\/spectrometers\/concavus-spectrometers\/","title":{"rendered":"Concavus Spectrometers \u51f9\u9762\u5149\u67f5\u5149\u8b5c\u5100"},"content":{"rendered":"<p>Get the \u00a0<a href=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/concavus.pdf\">Concavus\u00a0Data Sheet<\/a><\/p>\n<p>\u51f9\u9762\u6821\u6b63\u5149\u67f5\u5149\u8b5c\u5100<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" src=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/concavus.png\" alt=\"Concavus Spectrometers\" width=\"1387\" height=\"440\" \/><\/figure>\n<p>CONCAVUS\u00ae Fiber Optic Spectrometers use a novel optical design which is different from the conventional planar Czerny-Turner and flat field grating design(FFG). FFG design uses fewer optical components than planar Czerny-Turner for better thermal and mechanical stability, but it still suffers in spectral &amp; spatial resolution in large numerical aperture (NA) high light throughput optical design.<\/p>\n<p>CONCAVUS\u00ae spectrometers are based on Xiang System, which are comprised of an aberration corrected concave grating and transmissive aberration correctors. It dramatically reduces the residual aberration in FFG designs and increases the spectral and spatial resolution even with a large NA. Along with the solid opto-mechanical design, CONCAVUS\u00ae series spectrometers enable customers to achieve higher performance in their applications.<\/p>\n<ul>\n<li>The lowest Stray Light in the market.<\/li>\n<li>Minimized optical aberration for high finesse spectral images; Low distortion.<\/li>\n<li>Higher spectral and spatial resolution than conventional systems at high numerical aperture;<\/li>\n<li>Excellent spectral images at NA=0.22 or higher, even at NA=0.6;<\/li>\n<li>Fewer components and excellent thermal and mechanical stability;<\/li>\n<li>Original holographic grating for lower stray light;<\/li>\n<li>Higher linearity of spectral dispersion on detector for easier calibration.<\/li>\n<\/ul>\n<figure id=\"attachment_76\"><a href=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/optics.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-76 size-full\" src=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/optics.jpg\" alt=\"Concavus Optical Design\" width=\"956\" height=\"486\" srcset=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/optics.jpg 956w, https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/optics-300x153.jpg 300w\" sizes=\"auto, (max-width: 956px) 100vw, 956px\" \/><\/a><figcaption><span style=\"color: #0000ff;\"><strong>Concavus Optical Design<\/strong><\/span><\/figcaption><\/figure>\n<figure id=\"attachment_583\"><a href=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/spot_diagram.png\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-583 size-large\" src=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/spot_diagram-1024x379.png\" alt=\"Concave grating spectrometer spot diagram comparison\" width=\"1024\" height=\"379\" srcset=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/spot_diagram-1024x379.png 1024w, https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/spot_diagram-300x111.png 300w, https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/spot_diagram.png 1301w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption><span style=\"color: #0000ff;\"><strong>Concave grating spectrometer spot diagram comparison<\/strong><\/span><\/figcaption><\/figure>\n<figure id=\"attachment_77\"><a href=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/image005.png\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-77 size-full\" src=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/image005.png\" alt=\"Concavus 3D Rendition\" width=\"929\" height=\"579\" srcset=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/image005.png 929w, https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/image005-300x187.png 300w\" sizes=\"auto, (max-width: 929px) 100vw, 929px\" \/><\/a><figcaption><span style=\"color: #0000ff;\"><strong>Concavus 3D Rendition<\/strong><\/span><\/figcaption><\/figure>\n<p>Standard SMA connectors are used in CONCAVUS\u00ae systems. Custom input connector are possible.<\/p>\n<p>The CONCAVUS\u00ae series comes with a 16 bit AD converter, and USB2.0 high speed interface. It is especially designed for high resolution measurements. Its integration time can be adjusted from 10us to seconds to cover a wide range of light input power.<\/p>\n<p>The CONCAVUS\u00ae is equipped with terminal blocks Digital IO ports. These ports can be easily connected to other units for external triggering, shutter control, pulsed light sources, and GPIO controls and so on.<\/p>\n<figure id=\"attachment_580\"><a style=\"color: #0000ff;\" href=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/software.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-580 size-large\" src=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/software-1024x674.jpg\" alt=\"GratingWorks xspec GUI software\" width=\"1024\" height=\"674\" srcset=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/software-1024x674.jpg 1024w, https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/software-300x198.jpg 300w, https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/software.jpg 1490w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption><span style=\"color: #0000ff;\"><strong>GratingWorks xspec GUI software<\/strong><\/span><\/figcaption><\/figure>\n<p>The CONCAVUS\u00ae series runs on USB power and comes with SPEC_SOFT GUI software for Windows, a complete manual and USB interface cable. Multiple CONCAVUS USB spectrometers can be connected to a PC for simultaneous control.<\/p>\n\n<table id=\"tablepress-23-no-2\" class=\"tablepress tablepress-id-23\">\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">Optical Bench<\/td><td class=\"column-2\">Concave grating with an aberration corrector. Xiang Design<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Wavelength range<\/td><td class=\"column-2\">184 - 1100 nm<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Resolution<\/td><td class=\"column-2\">Depending on configuration (see product table)<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Stray light<\/td><td class=\"column-2\">< 0.05%<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Dark noise<\/td><td class=\"column-2\">30 stddev (no avg); less than 1 stddev with avg &amp; Nyquist notch filter<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Detector<\/td><td class=\"column-2\">Toshiba TCD1304DG, 3648 pixels, 8 um x 200 um<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Signal\/ Noise<\/td><td class=\"column-2\">>380, no averaging  <a href=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/noise.pdf\" target=\"_blank\">(Read More)<\/a><\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Dynamic range<\/td><td class=\"column-2\">>2300 (No Averaging); > 10,000 (averaging) <\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">AD converter<\/td><td class=\"column-2\">16 bit, 1 MHz, 3.7 mx sampling time per spectrum<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Integration time<\/td><td class=\"column-2\">10 us - 65 s<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Interface<\/td><td class=\"column-2\">(standard SMA 905, others possible); USB 2.0 RS-232, 115.200 bps (optional)<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Max transfer speed to PC<\/td><td class=\"column-2\">275 scans\/s (USB HS)<br \/>\n70 scans\/s (USB2 FS)<br \/>\n1.2 scans\/s (RS-232)<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Digital IO<\/td><td class=\"column-2\">Terminal Block. 6 GPIOs, External Trigger, Lamp Strobe<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Power supply<\/td><td class=\"column-2\">USB power, 110 mA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n<table id=\"tablepress-22-no-2\" class=\"tablepress tablepress-id-22\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Series <\/th><th class=\"column-2\">Range (nm)<\/th><th class=\"column-3\">Spectral Range<\/th><th class=\"column-4\">FWHM\/25 um Slit<\/th><th class=\"column-5\">FWHM\/50 um Slit<\/th><th class=\"column-6\">Dimension (mm)<\/th><th class=\"column-7\">Weight (g)<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">HR-01<\/td><td class=\"column-2\">350-1100<\/td><td class=\"column-3\">750<\/td><td class=\"column-4\">0.8<\/td><td class=\"column-5\">1.4<\/td><td class=\"column-6\">142x81x60.5<br \/>\n<br \/>\n<\/td><td class=\"column-7\">735<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">HR-02<\/td><td class=\"column-2\">190-1100<\/td><td class=\"column-3\">910<\/td><td class=\"column-4\">1.0<\/td><td class=\"column-5\">1.7<\/td><td class=\"column-6\">140x76.3x64.5<br \/>\n<br \/>\n<\/td><td class=\"column-7\">705<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">HR-03<\/td><td class=\"column-2\">184-410<\/td><td class=\"column-3\">226<\/td><td class=\"column-4\">0.2<\/td><td class=\"column-5\">0.36<\/td><td class=\"column-6\">147.5x88.5x61.5<br \/>\n<br \/>\n<\/td><td class=\"column-7\">780<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">HR-04<\/td><td class=\"column-2\">380-780<\/td><td class=\"column-3\">400<\/td><td class=\"column-4\">0.9<\/td><td class=\"column-5\">1.5<\/td><td class=\"column-6\">103x68x57.5<\/td><td class=\"column-7\">565<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">HR-05<\/td><td class=\"column-2\">190-550<\/td><td class=\"column-3\">360<\/td><td class=\"column-4\">0.38<\/td><td class=\"column-5\">0.68<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">HR-06<\/td><td class=\"column-2\">550-950<\/td><td class=\"column-3\">400<\/td><td class=\"column-4\">0.45<\/td><td class=\"column-5\">0.73<\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Raman 785<\/td><td class=\"column-2\">795-975<\/td><td class=\"column-3\">200<\/td><td class=\"column-4\"><\/td><td class=\"column-5\"><\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Raman 532<\/td><td class=\"column-2\">537-667<\/td><td class=\"column-3\">130<\/td><td class=\"column-4\"><\/td><td class=\"column-5\"><\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n<p class=\"auto-style1\">* <em>\u00a0please note that not all pixels will be used for the spectral\u00a0range. Actual spectral range may extend beyond the specified range.\u00a0<\/em><\/p>\n<p class=\"auto-style1\"><em><strong>Ordering Information:<\/strong><\/em><br \/>\n<em>HR01: HR01 spectrometer, 3648 pixel CCD detector, USB cable, XSpec_soft, 25um slit. <\/em><br \/>\n<em>Options:<\/em><br \/>\n<em>SLIT-XX: XX=10, 25, 50, 100, 200, 500um<\/em><\/p>\n<p><span style=\"color: #0000ff;\"><span style=\"color: #3366ff;\"><a style=\"color: #3366ff;\" href=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/temp.pdf\">Temperature Stability Testing<\/a><\/span><\/span><\/p>\n<p><a href=\"https:\/\/www.gratingworks.com\/wp-content\/uploads\/2015\/06\/noise.pdf\">Spectrometer Noise Analysis and Testing<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Get the \u00a0Concavus\u00a0Data Sheet \u51f9\u9762\u6821\u6b63\u5149\u67f5\u5149\u8b5c\u5100 CONCAVUS\u00ae Fiber  [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":17,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-45","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.gratingworks.com\/zh\/wp-json\/wp\/v2\/pages\/45","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gratingworks.com\/zh\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.gratingworks.com\/zh\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.gratingworks.com\/zh\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gratingworks.com\/zh\/wp-json\/wp\/v2\/comments?post=45"}],"version-history":[{"count":3,"href":"https:\/\/www.gratingworks.com\/zh\/wp-json\/wp\/v2\/pages\/45\/revisions"}],"predecessor-version":[{"id":1057,"href":"https:\/\/www.gratingworks.com\/zh\/wp-json\/wp\/v2\/pages\/45\/revisions\/1057"}],"up":[{"embeddable":true,"href":"https:\/\/www.gratingworks.com\/zh\/wp-json\/wp\/v2\/pages\/17"}],"wp:attachment":[{"href":"https:\/\/www.gratingworks.com\/zh\/wp-json\/wp\/v2\/media?parent=45"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}